Enter four numbers from your site and get the first-pass design: delivered water, drive-pipe size and length, power balance — plus a few honest warnings.

Your site

60%
Try:

First-pass design

Delivered flow q—
Per day, running 24/7—
Wasted flow (the fuel)—
Lift ratio h/H——
Suggested drive pipe—
Drive pipe length (3–7 × H)—
Input water power—
Output water power—
Total through the ram—

    How this works

    The calculator applies the standard first-order relations from the Physics page:

    q = η · Q · H / h   ·   Pin = ρg·Q·H   ·   Pout = ρg·q·h   ·   D = √(4Q / (π·v)), v = 1.5 m/s

    Drive pipe length is suggested as the classic 3–7 × H band; lift-ratio verdicts use the 6:1 / 10:1 thresholds.

    ⚠️
    First-pass means first-pass

    Real rams lose a few percent to friction, valve timing, temperature and wear, and commercial manufacturers publish measured capacity tables that differ from theory. Treat these numbers as a feasibility check and starting point — then tune on site (see tuning).