RamPump KB

Section 40 · Reference

Glossary

The vocabulary of rams — the words Victorian millwrights, development engineers and YouTube builders all use, sometimes for the same part.

Air chamber · pressure vessel, air vessel, cushion tank
Sealed vessel above the delivery check valve holding trapped air that cushions the slam, smooths delivery flow, and keeps pushing water between beats. Loses its air gradually to dissolution; see recharging.
Beat · cycle, stroke
One complete operating cycle of the ram — charge, slam, delivery, recoil. Small rams beat roughly 30–100 times per minute.
Bélier hydraulique
French for "hydraulic ram" — Montgolfier's original name for the device in 1796.
Clack valve · waste valve, impulse valve
The weighted or spring-loaded valve that opens to let water accelerate and slams shut to trigger the hammer. The ram's throttle and its ignition switch in one.
Compound ram
A ram with separated drive and delivery circuits, allowing potable water to be pumped using non-potable drive water.
D'Aubuisson efficiency
Energy efficiency measured against all water passing through the ram: q·h/(Q·H). Typically 60–80% for a healthy ram. See Physics.
Delivery check valve · NRV, non-return valve
The one-way valve that admits water to the air chamber during the pressure spike and reseats when pressure falls, holding the uphill column.
Delivery head · lift, h
Vertical rise from the ram to the delivery tank's water surface. Horizontal distance costs only friction, not head.
Drive flow · Q
Total water flowing through the ram per unit time — delivered flow plus waste flow.
Drive head · fall, supply head, H
Vertical drop from the source water surface to the ram. The ram's power supply, measured in metres.
Drive pipe · supply pipe, impulse pipe
The rigid pipe from intake to ram, ideally 3–7× the fall, constant diameter, as straight as practical. Its inertia is the engine's flywheel.
Drive tank · forebay, fosset, header tank
Small settling tank at the source that houses the screened intake and steadies the supply.
Hydram
Contraction of "hydraulic ram" — the ram pump itself.
Joukowsky equation
Δp = ρ·c·Δv: the pressure rise when a water column is stopped abruptly. The reason a 2 m fall can pump to 20 m. See Physics.
Lift ratio
Delivery head ÷ fall (h/H). Sweet spot 2–6:1; workable to about 10:1.
Papa Pump
Modern commercial ram using a concentric venturi waste valve (F. P. Selwyn, patented 1996/2001).
Rankine efficiency
Figure of merit counting only the rejected water as input: q·h/((Q−q)·H). Always ≥ D'Aubuisson; can exceed 100% at low lift ratios, so it is not a true efficiency.
Recoil
The pressure rebound after the delivery phase; the reflected suction wave that helps the waste valve reopen and resets the beat.
Snifter · snifting valve, air recharge
Tiny hole or valve near the delivery check that inhales a bubble of air each beat, replenishing the air chamber.
Static head
Pressure exerted by a still water column: ~0.098 bar per metre. The benchmark the spike must beat at the delivery valve.
Volumetric efficiency
Fraction of source water actually delivered: q/Q ≈ η·H/h. Typically 5–20% — the rest is the fuel.
Waste flow · spent flow
Water leaving through the waste valve: Q − q. Clean water, returned below the ram — ideally re-used.
Water hammer · hydraulic shock, "knocking"
The pressure transient when moving water is stopped suddenly. Household nuisance; ram power source.
Wave speed · c, celerity
Speed of the pressure wave in the pipe: ~1200–1400 m/s in rigid steel, 300–500 m/s in PVC. Sets the valve-timing mathematics.
Waterlogged chamber
An air chamber whose cushion has dissolved away. Symptoms: banging delivery line, harsh slams. Cure: recharge the air.