RamPump KB

Section 14 · Design & Build

Source & site assessment

Every ram design starts with two numbers — how far the water falls, and how much of it you can spare. Getting those wrong is the cheapest mistake to avoid and the most expensive to discover afterwards.

Gauging what the stream actually carries

"About a bucket a second" is not a measurement, and it is the number the whole design rests on. A ram's delivered output is directly proportional to drive flow, so a 50% error in flow is a 50% error in the water you plan to drink. Gauging properly costs an afternoon.

Fall is easy — flow is not

The fall H is the vertical drop from the water surface at the intake to the ram's waste valve, and a level, a long clear hose, or a builder's level and staff will give it to within a few centimetres. Flow Q is the hard one: it changes day to day, it hides in weed and boulders, and it is almost always estimated by eye.

Pick the method that matches the flow you expect and the time you have.
MethodSuitsEffortTypical accuracy
Bucket / jug & stopwatchunder ~5 L/s — springs, small runsminutes±5%
Float & velocity-area~5 L/s to 1 m³/san hour±20–30%
90° V-notch weirunder ~30 L/shalf a day, needs a temporary dam±5%
Rectangular weir30 L/s to 1 m³/sa day±10%
Salt dilutionrocky, turbulent, un-dammable channelsan hour plus a conductivity meter±10%

Bucket and stopwatch

The honest method, and the only one that needs nothing but a container and a phone. Divert the whole flow into a bucket, time how long it takes to fill a known volume, and repeat three or four times so a single splash cannot skew the answer. If the stream is too big to divert, it is too big for this method — move on.

Float and velocity-area

Choose a reach that is straight, uniform and free of weed or boulders, and mark two lines a few metres apart. Measure the channel's cross-section (width and depth at several points) to get an area A in m², then time a floating stick or an orange over the marked distance to get a surface velocity.

Surface water moves faster than the water below it, so a single float over-reads. Multiply the surface velocity by roughly 0.8–0.9 for a rough channel and nearer 0.9 for a smooth one: Q ≈ A · vsurface · k. This is why the method is quoted at ±20–30%: it is a good sanity check and a poor design number.

Weirs — the accurate option

A sharp-crested weir turns flow into a depth, and depth is easy to measure accurately. For a 90° V-notch (Thomson) weir, with the head H measured upstream of the notch and clear of the draw-down:

Q = 1.417 · H5/2

Q in m³/s and H in metres. The constant assumes a discharge coefficient of about 0.60 — the classic Thomson form. The current standard (ISO, ASTM and USBR) is the Kindsvater–Shen equation, which uses a fitted coefficient and a small correction to the head. Over the useful range the two agree to within about 2% above a 150 mm head, but they diverge by up to 9% at the smallest usable heads — and Kindsvater–Shen reads higher there, which is the optimistic direction. Where the reading matters, use the standard equation rather than a fixed constant. A 100 mm head gives about 4.5 L/s and a 200 mm head about 25 L/s, so the notch is very sensitive at low flows — exactly where a ram is designed.

For larger flows a suppressed rectangular weir (no end contractions) follows the Francis form Q = 1.84 · L · H3/2, again in m³/s with L the crest length in metres.

Either way, a weir only reads as accurately as it is built to the geometry the equation assumes. These are the requirements worth knowing before you spend a day on the structure:

Salt dilution

Where the channel is too rocky to dam, inject a known mass of salt (or a known volume of strong brine) into the flow and measure how much it is diluted by the time it reaches a downstream conductivity probe. It copes with turbulent, boulder-strewn streams where nothing else works, needs no structure, and is the standard method for upland catchments. It is worth hiring or borrowing a meter for a day if your stream fits that description.

⚠️
Measure where the water will actually be taken

A gauge reading taken 200 m upstream of the intake is worthless if a farmer already diverts half the flow between the two points. Gauge at the intake site, and make sure nothing is abstracting between your intake and the ram.

Designing for the dry season

This is the single most common way a ram pump project fails, and it fails invisibly for a whole season before anyone notices. The ram is sized on a spring measurement, it works beautifully from October to April, and in August it clacks slowly, delivers a trickle, and eventually stops. Nothing is broken; the stream simply does not carry what it did in April.

The design case is the lowest flow, not the average

A ram has no throttle and no switch: it takes whatever arrives and stops when the drive flow drops below the point where it can slam the waste valve. Size for the low flow you expect to see in the worst month, not for the flow you happened to measure. In hydrology that number is often written Q95 — the flow exceeded 95% of the time — and it is the correct basis for a water supply that must not fail.

Finding it in the field, in order of preference:

⚖️
A ram is forgiving of a small flow

Where a turbine or a solar pump needs a certain flow before it is worth installing at all, a ram will happily take a litre a second — or less, if the fall is good. Designing for the dry season costs you a smaller ram and a longer drive pipe, not a different technology.

Leave water in the channel

A ram is unusual in that its waste stream returns to the stream bed, so the net abstraction is only the delivered flow — which is typically a small fraction of what flows past. That makes a ram an easy case to justify environmentally, but it is not a licence to take the lot:

Floods, silt and the intake

You size the ram for the dry season, but you must build the intake for the wet one. Floods arrive with the energy to move boulders, silt up a forebay and rip an intake off its mounting. The design consequence is a split personality:

Silt is the quiet killer: an intake that takes its water from just above the bed draws grit into the drive pipe, where it erodes valve seats and wears the delivery check valve. Draw from just below the surface, not from the bottom (see intake & forebay).

✓
The assessment in one line

Measure the fall accurately, measure the flow at least twice in different seasons, design the ram on the lowest flow and the intake on the flood, and leave some water in the channel. Do that and the rest of the design has solid ground under it.

Next: turn those two numbers into a machine — see Design & Sizing, or check the arithmetic with the sizing calculator. Once water is delivered, the next question is where it goes: Storage & distribution.